FAQ/Contact usProducts FAQs

Multilayer Ceramic Capacitor Working Voltage

When using multilayer ceramic capacitors, be careful not to apply a voltage in excess of the rated voltage. Please make sure that the sum of the DC voltage and peak voltage of the superimposed ripple current is less than the rated voltage.

You can greatly reduce the rate of failure by using the capacitor at reduced voltage. Even if using the product at the rated voltage or lower, please consult us if you plan to use it in a circuit that will continuously apply a high frequency voltage or steep pulse voltage.
Tags
Precaution

If you have any questions or inquiries that do not apply to the above, please contact us at the following address.

Products Inquiries