Precautions for Using Multiple Connected Supercapacitors

When connecting supercapacitors in series, insert a voltage balancing circuit in parallel with the supercapacitors to suppress voltage imbalance among them.However, a certain amount of voltage spread will occur even with a voltage balancing circuit in place.  So this should be taken into account and a sufficient amount of margin included.

[Fig. 1] Example of voltage balancing circuit

If nothing is done to balance voltage, the variation in characteristics between supercapacitors may cause them to become unbalanced, and result in some cells experiencing voltages in excess of their rated voltage.
Tags
Precaution

If you have any questions or inquiries that do not apply to the above, please contact us at the following address.