Products LineupSupercapacitors

Supercapacitors DLCAP™ Module MDKA150S8R3PE6111A

  • Over Voltage Detection Circuit Installed
  • Balance Circuit Installed

Product Information

Part Number MDKA150S8R3PE6111A
Series DKA
Category Temperature Range -40~70 ℃
Rated Voltage 15 Vdc
Capacitance 8.3 F
Capacitance Tolerance +10 / -15%
Size W 152mm
Size D 65mm
Size H 28mm
Internal Resistance (Typ.) 74.2 mΩ
Internal Resistance (Max.) 87.4 mΩ
Energy Storage 0.26 Wh
Reference Weight 0.2 kg
RoHS Compliant Compliant

Product Information

Project Specifications
Temperature characteristics Capacitance Change ≦±30% of the measured value at 20℃ (-40℃)
Internal Resistance Change ≦600% of the internal resistance maximum value given in the ratings tables
Load Life Test After the capacitors are subjected to the rated DC voltage at 70℃ for 1000 hours, the following specifications shall be satisfied when they are restored to 20℃.
Capacitance Change ≦±30% of the initial measured value at 20℃
Internal Resistance Change ≦200% of the internal resistance maximum value given in the ratings tables
After the capacitors are subjected to the rated DC voltage at 60℃ for 2000 hours, the following specifications shall be satisfied when they are restored to 20℃.
Capacitance Change ≦±30% of the initial measured value at 20℃
Internal Resistance Change ≦200% of the internal resistance maximum value given in the ratings tables
Bias Humidity Test After the capacitors are left at 60℃ and 90 to 95%RH for 500 hours without voltage applied, the following specifications shall be satisfied when they are restored to 20℃.
Capacitance Change ≦±30% of the initial measured value at 20℃
Internal Resistance Change ≦200% of the internal resistance maximum value given in the ratings tables

Dimension [mm]

Dimension [mm]

Characteristics Data

Temperature Dependance of Capacitance & DCIR
  • Temperature Dependance of Capacitance & DCIR

  • Temperature Dependance of Capacitance & DCIR

70℃ Load Life Test
  • 70℃ Load Life Test

  • 70℃ Load Life Test

60℃ Load Life Test
  • 60℃ Load Life Test

  • 60℃ Load Life Test