≦1200% of the internal resistance maximum value given in the ratings tables
Load Life Test
After the capacitors are subjected to the rated DC voltage at 70℃ for 2000 hours, the following specifications shall be satisfied when they are restored to 20℃.
Capacitance Change
Capacitance Change
Internal Resistance Change
≦300% of the internal resistance maximum value given in the ratings tables
Bias Humidity Test
After the capacitors are left at 60℃ and 90 to 95%RH for 500 hours without voltage applied, the following specifications shall be satisfied when they are restored to 20℃.
Capacitance Change
Capacitance Change
Internal Resistance Change
≦300% of the internal resistance maximum value given in the ratings tables
Insulation Resistance
The measured value between the lumped terminal and the case using 500Vdc insulation resistance meter shall be more than 100MΩ.
Insulation Withstand Voltage
No abnormality after the AC 2500V is applied between lumped terminal and package for 1 minute. package for 1 minute.